Source code for bragi_quantum.experiments.nodes.coupler.cz_chevron.parameters

# ══════════════════════════════════════════════════════════════════════════
#     ___   ___ ___   _      _   ___
#    / _ \ / __|_  ) | |    /_\ | _ )
#   | (_) | (__ / /  | |__ / _ \| _ \
#    \__\_\\___/___| |____/_/ \_\___/
#
#   QC2 @ CHALMERS CALIBRATION TOOLKIT
#   (c) 2026 Chalmers University of Technology and Project Contributors
# ──────────────────────────────────────────────────────────────────────────
#   Licensed under the Apache License, Version 2.0 (the "License");
#   you may not use this file except in compliance with the License.
#   You may obtain a copy of the License at
#
#       https://www.apache.org/licenses/LICENSE-2.0
#
#   Unless required by applicable law or agreed to in writing, software
#   distributed under the License is distributed on an "AS IS" BASIS,
#   WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
#   See the License for the specific language governing permissions and
#   limitations under the License.
# ──────────────────────────────────────────────────────────────────────────
#   CONTRIBUTORS list:
#
#   Joel Sandås, joel.sandas@chalmers.se
#   Axel Andersson, axean@chalmers.se
#   Matteo Robbiati, robbiati@chalmers.se
#   Michele Faucci Giannelli, faucci@chalmers.se
# ══════════════════════════════════════════════════════════════════════════


from typing import override

from pydantic import Field

from bragi_quantum.experiments.abstract.parameter_fields import acquisition_field
from bragi_quantum.experiments.abstract.parameters import BaseParameters, BaseQoi


[docs] class CZChevronParameters(BaseParameters): """ Parameters for the CZ chevron: sweeping the coupler's flux pulse frequency and duration (amplitude held fixed) to find whether a usable |11>-|20> (or |11>-|02>) avoided crossing exists at a candidate current, and to refine the CZ pulse duration itself. Ported from tergite-autocalibration (CZChevronNode). """ repetitions: int = acquisition_field( default=1024, description="Repetitions (averages) per point." ) # Frequency sweep (Hz), centered on each coupler's CZ transition frequency # (computed from the qubits' calibrated 01/12 clock frequencies). frequency_sweep: float = acquisition_field( default=10e6, description="Half-width (Hz) of the CZ pulse frequency sweep." ) frequency_bins: int = acquisition_field( default=15, description="Number of frequency points." ) # Duration sweep (s) of the CZ flux pulse. duration_min: float = acquisition_field( default=20e-9, description="Start of the duration sweep (s)." ) duration_max: float = acquisition_field( default=700e-9, description="End of the duration sweep (s)." ) duration_bins: int = acquisition_field( default=30, description="Number of duration points." ) # CZ pulse amplitude, fixed for this chevron scan. cz_pulse_amplitude: float = acquisition_field( default=0.5, ge=-1, le=1, description="Amplitude of the CZ flux pulse (fullscale).", ) # Which avoided crossing the CZ pulse targets: "20" drives the first # qubit of the coupler (by name order) towards |2>, the second towards # |0>; "02" is the reverse. cz_transition: str = acquisition_field( default="20", description="Targeted transition: '20' or '02'." ) cz_half_frequency_wp: bool = acquisition_field( default=False, description="Center the frequency sweep at half the computed CZ " "transition frequency, for couplers operated at a half-frequency " "working point.", ) # Informational only: the DC current the coupler is currently parked at # when this scan runs (set by a previous cz_currents_from_spectroscopies # run). Not applied to hardware by this node. parking_current: float = Field( default=0.0, description="Coupler DC parking current (A), for plot labels only." ) # Flux-line IF/LO scheme: the CZ pulse clock is programmed at # -frequency + downconvert_frequency. Hardware-wiring specific; override # per coupler via custom_parameters for lines with a different LO setup. downconvert_frequency: float = Field( default=4.4e9, description="Flux-line downconversion offset (Hz)." ) # SPI-rack safety limit — do not change casually. max_transition_frequency: float = Field( default=1e9, description="Couplers whose computed transition frequency exceeds " "this (Hz) are skipped entirely.", ) # If more than this fraction of the 9 support-trace fits (neighboring # frequencies around the chosen working point) fail to resolve a genuine # duration oscillation, the working point is discarded even if the # coarser two-qubit compatibility check passed. trace_fit_failure_threshold: float = acquisition_field( default=0.66, description="Support-trace fit failure fraction above which a " "working point is discarded.", )
[docs] class CZChevronQOI(BaseQoi): """ Quantities of Interest for the CZ chevron on one coupler: the (frequency, duration) working point found, plus diagnostics on how many of the neighboring support-trace fits resolved a genuine oscillation. """ cz_pulse_frequency: float = 0.0 cz_pulse_frequency_error: float = 0.0 cz_pulse_duration: float = 0.0 cz_pulse_duration_error: float = 0.0 # JSON-encoded list of [frequency, avg_period] pairs for the neighboring # support-trace fits that converged to a resolvable oscillation period. cz_chevron_trace_periods: str = "[]" # Fraction of the neighboring support traces whose fit failed to resolve # a genuine oscillation (see CZChevronAnalysis.TRACE_FIT_FAILURE_THRESHOLD). cz_chevron_trace_fit_failure_fraction: float = 0.0
[docs] def items(self): """ Iterate like a mapping so bragi_quantum.datalayer's ``update_redis_trusted_values`` can inspect the QOI keys when routing coupler results. """ return self.to_dict().items()
[docs] @override def to_dict(self) -> dict: return { "cz.cz_freq": self.cz_pulse_frequency, "cz.square_duration": self.cz_pulse_duration, "cz_chevron_trace_fit_failure_fraction": self.cz_chevron_trace_fit_failure_fraction, }
[docs] def to_redis_dict(self) -> dict[str, dict]: # "cz:cz_freq" / "cz:square_duration" follow the device # 'submodule:field' convention so BaseNode._apply_qoi_to_device writes # them straight onto the coupler edge's ParametricCZSubmodule. return { "cz:cz_freq": { "value": self.cz_pulse_frequency, "error": self.cz_pulse_frequency_error, }, "cz:square_duration": { "value": self.cz_pulse_duration, "error": self.cz_pulse_duration_error, }, "cz_chevron_trace_fit_failure_fraction": { "value": self.cz_chevron_trace_fit_failure_fraction, "error": 0.0, }, }