Source code for bragi_quantum.experiments.abstract.node

# ══════════════════════════════════════════════════════════════════════════
#     ___   ___ ___   _      _   ___
#    / _ \ / __|_  ) | |    /_\ | _ )
#   | (_) | (__ / /  | |__ / _ \| _ \
#    \__\_\\___/___| |____/_/ \_\___/
#
#   QC2 @ CHALMERS CALIBRATION TOOLKIT
#   (c) 2026 Chalmers University of Technology and Project Contributors
# ──────────────────────────────────────────────────────────────────────────
#   Licensed under the Apache License, Version 2.0 (the "License");
#   you may not use this file except in compliance with the License.
#   You may obtain a copy of the License at
#
#       https://www.apache.org/licenses/LICENSE-2.0
#
#   Unless required by applicable law or agreed to in writing, software
#   distributed under the License is distributed on an "AS IS" BASIS,
#   WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
#   See the License for the specific language governing permissions and
#   limitations under the License.
# ──────────────────────────────────────────────────────────────────────────
#   CONTRIBUTORS list:
#
#   Axel Andersson, axean@chalmers.se
#   Matteo Robbiati, robbiati@chalmers.se
#   Michele Faucci Giannelli, faucci@chalmers.se
#   Abdullah-Al Amin, alamina@chalmers.se
#   Yanchen Lin, linya@chalmers.se
# ══════════════════════════════════════════════════════════════════════════


# This code is part of Tergite
#
# (C) Copyright Eleftherios Moschandreou 2023, 2024
# (C) Copyright Liangyu Chen 2023, 2024
# (C) Copyright Stefan Hill 2024
# (C) Copyright Michele Faucci Giannelli 2024, 2025
# (C) Copyright Pontus Vikstål 2024, 2025
#
# This code is licensed under the Apache License, Version 2.0. You may
# obtain a copy of this license in the LICENSE.txt file in the root directory
# of this source tree or at http://www.apache.org/licenses/LICENSE-2.0.
#
# Any modifications or derivative works of this code must retain this
# copyright notice, and modified files need to carry a notice indicating
# that they have been altered from the originals.
#
# Modified from tergite-autocalibration
# (https://github.com/tergite/tergite-autocalibration), file:
#   tergite_autocalibration/lib/base/node.py


import abc
from pathlib import Path
from typing import Any, override

import numpy as np
import xarray
from colorama import init as colorama_init
from qblox_scheduler import QuantumDevice
from qblox_scheduler.qblox.hardware_agent import HardwareAgent
from qblox_scheduler.schedules.schedule import CompiledSchedule
from qcodes.instrument import Instrument

import bragi_quantum.experiments.utils.dataset_utils as ds_utils
from bragi_quantum.datalayer.managing.dataset import save_dataset
from bragi_quantum.datalayer.managing.redis import (
    record_calibration_metadata,
    update_redis_trusted_values,
)
from bragi_quantum.datalayer.managing.session import ActiveSession
from bragi_quantum.datalayer.managing.time_tracing import TimingTraceCategory
from bragi_quantum.datalayer.models.coupler import ExtendedCompositeSquareEdge
from bragi_quantum.datalayer.models.qubit import ExtendedTransmon
from bragi_quantum.datalayer.utils.device.spi import SpiDAC
from bragi_quantum.datalayer.utils.logging import logger
from bragi_quantum.datalayer.utils.mode import ExecutionMode
from bragi_quantum.experiments.abstract.analysis import Analysis
from bragi_quantum.experiments.abstract.errors import (
    ExperimentBuildingError,
    ExperimentParameterError,
)
from bragi_quantum.experiments.abstract.measurement import BaseMeasurement
from bragi_quantum.experiments.abstract.parameters import BaseParameters, BaseQoi
from bragi_quantum.experiments.utils import calibration_points as cal
from bragi_quantum.experiments.utils.schedule_execution import execute_schedule
from bragi_quantum.experiments.utils.timing import timed

colorama_init()


[docs] class BaseNode(abc.ABC): measurement_cls: "BaseMeasurement" analysis_cls: "Analysis" # Automatically append per-state calibration points (on dedicated CAL_ # acquisition channels) after the user schedule, provided every qubit has # a calibrated X gate. Opt-in: a node's schedule_function must return a # schedule with repetitions == 1 (its averaging expressed as a loop # register) before this can be enabled, so it defaults to False until # each node is migrated. append_calibration_points: bool = False # With append_calibration_points=True, fail the build instead of silently # continuing if calibration points can't be appended. require_calibration_points: bool = False def __init__( self, parameters: BaseParameters, qoi_cls: BaseQoi, ): self.parameters = parameters self.qoi_cls = qoi_cls self.name = parameters.name self.node_dictionary = {} self._results = {} self.schedule_samplespace = {} self.external_samplespace = {} self.all_qubits = parameters.qubits # Resolve per-qubit custom_parameters overrides ONCE, here in the base, so # every node reads measurement-time fields per qubit (via # ``self.parameters_by_qubit[q].<field>``) without re-implementing — or # forgetting — the resolution. Overrides are applied at compile time, and # forgetting to apply them is exactly the class of bug this prevents. # (Coupler nodes additionally get ``parameters_by_coupler``; see CouplerNode.) self.parameters_by_qubit = parameters.resolved_by_qubit() self.element_type: str = None # 'qubit' or 'coupler' # These may be modified while the node runs self.outer_schedule_samplespace = {} self.reduced_external_samplespace = {} self.schedule_keywords = {} # Track dataset path for bragi_quantum.gui replot metadata self.dataset_directory: Path | None = None self.dataset_basename: str = self.parameters.name # Initialize from active SessionContext self._initialize_from_session() # Initialize samplespace after device configuration is set up # (required for properties that depend on device_manager) try: self.samplespace = self.schedule_samplespace | self.external_samplespace except Exception: self.samplespace = {} # Fallback if properties aren't ready yet def _initialize_from_session(self) -> None: """ Retrieve hardware configuration, device, and execution options from active SessionContext. This replaces the previous approach of manually passing parameters through the call stack. """ # TODO: remove initialization of all these attributes because we can directly # assign an attribute which his the session itself try: session = ActiveSession.get() except RuntimeError: raise RuntimeError( "Node initialization requires an active calibration session. " "Ensure you are using CalibrationOrchestrator.calibration_session() context." ) # Retrieve device configuration and related objects from session self.device: QuantumDevice = session.device self._validate_requested_components() # DeviceConfiguration wrapping the device; holds extended_state, the # analysis quantities not reflected in the live QuantumDevice. self.device_config = session.device_config self.hardware_agent: HardwareAgent = session.hardware_agent self.spi_manager: SpiDAC = session.spi_dac_handler # TODO: we should support the case where REDIS is not used self.redis_connection = session.redis_connection # Retrieve execution options from session pdf_filepath = session.session_options.pdf_report_filepath if pdf_filepath: # If relative path, resolve against session root; otherwise use absolute path if ( isinstance(pdf_filepath, (str, Path)) and not Path(pdf_filepath).is_absolute() ): self.pdf_report_path = session.root_path / pdf_filepath else: self.pdf_report_path = ( Path(pdf_filepath) if isinstance(pdf_filepath, str) else pdf_filepath ) else: self.pdf_report_path = None self.produce_support_figures = session.session_options.produce_support_figures self._save_cluster_metadata_to_disk = ( session.session_options.save_cluster_metadata_to_disk ) # Store execution mode for later use in measure_node/calibrate self._execution_mode = session.session_options.execution_mode # Extract cluster names from hardware_description section. A config may # describe multiple clusters hardware_desc = ( session.cluster_config.hardware_description if session.cluster_config else {} ) self._cluster_names = list(hardware_desc.keys()) if hardware_desc else [] def _validate_requested_components(self) -> None: """Fail fast if ``parameters.qubits``/``couplers`` names aren't on the device. Names must match the device config exactly (no normalization is applied anywhere in the toolkit), so a typo or a stale naming convention would otherwise only surface as a ``KeyError`` deep inside schedule/samplespace construction. Checking here, right after the device becomes available, catches it before any node-specific work starts. """ unknown_qubits = sorted(set(self.parameters.qubits) - set(self.device.elements)) unknown_couplers = sorted( set(self.parameters.couplers) - set(self.device.edges) ) if not unknown_qubits and not unknown_couplers: return problems = [] if unknown_qubits: problems.append(f"qubit(s) {unknown_qubits}") if unknown_couplers: problems.append(f"coupler(s) {unknown_couplers}") raise ExperimentParameterError( f"Unknown {' and '.join(problems)} requested; device has qubits " f"{sorted(self.device.elements)} and couplers {sorted(self.device.edges)}." ) def _detect_element_kind(self) -> str: """Determine whether this node operates on qubits or couplers.""" # Prefer explicit assignment, then read the analysis class's element_kind. if self.element_type: return self.element_type return getattr(self.analysis_cls, "element_kind", "qubit") def _build_replot_metadata(self) -> dict[str, Any]: """ Build metadata needed for replaying this node's analysis via bragi_quantum.gui. This metadata allows the replot server to re-instantiate the analysis class, rebuild fit results, and render plots on demand using recorded parameters and measurement data. Returns: Dict with keys: - analysis_module: Module path of the analysis class - analysis_class: Name of the analysis class - parameters_module: Module path of the parameters class - parameters_class: Name of the parameters class - qoi_module: Module path of the QOI class (optional) - qoi_class: Name of the QOI class (optional) - dataset_dir: Directory containing HDF5 measurement files - dataset_basename: Base name for dataset files (e.g., "resonator_wide") - element_kind: "qubit" or "coupler" """ meta: dict[str, Any] = { "analysis_module": self.analysis_cls.__module__, "analysis_class": self.analysis_cls.__name__, "parameters_module": self.parameters.__class__.__module__, "parameters_class": self.parameters.__class__.__name__, "element_kind": self._detect_element_kind(), } # Optional: QOI class if self.qoi_cls: meta["qoi_module"] = self.qoi_cls.__module__ meta["qoi_class"] = self.qoi_cls.__name__ # Dataset location (set during measure_node by subclasses) if hasattr(self, "dataset_directory") and self.dataset_directory: meta["dataset_dir"] = str(self.dataset_directory) meta["dataset_basename"] = getattr( self, "dataset_basename", self.parameters.name ) return meta
[docs] def measure_node(self, *, execution_mode: ExecutionMode) -> xarray.Dataset: """ To be implemented by the Classes that define the Node Type: ScheduleNode or ExternalParameterNode """ return xarray.Dataset()
@abc.abstractmethod def _build_measurement(self): """Polymorphic hook implemented by subclasses""" raise NotImplementedError
[docs] def execute(self): """ Execute the full calibration pipeline for this node. Derives the data path from the active session's root path, using a unique per-invocation folder so repeated runs don't collide. """ session = ActiveSession.get() dir_name = ActiveSession.next_node_dir_name(self.name) data_path = session.root_path / dir_name data_path.mkdir(parents=True, exist_ok=True) # Store so _build_replot_metadata() can find it when recording the # timeline step after analysis completes. self.dataset_directory = data_path self.calibrate(data_path) return self._results
[docs] def pre_measurement_operation(self): """ To be implemented by the child measurement nodes """
[docs] def initial_operation(self): """ To be implemented by the child measurement nodes. This is called before the execution of each and every iteration of the samples of the external samplespace. See coupler_spectroscopy for examples. """
[docs] def final_operation(self): """ To be implemented by the child measurement nodes. This is called after ALL the iteration samples of the external samplespace have been executed. e.g. set back the dc_current to 0 in coupler_spectroscopy. See coupler_spectroscopy for examples. """
[docs] def precompile(self, schedule_samplespace: dict) -> CompiledSchedule: with timed( "Schedule build took: ", timing_category=TimingTraceCategory.PREPARATION ): measurement_obj = self._build_measurement() schedule = measurement_obj.schedule_function( **schedule_samplespace, **self.schedule_keywords, ) if self.append_calibration_points: if schedule.repetitions != 1: raise ExperimentBuildingError( f"{type(measurement_obj).__name__}.schedule_function returned a " f"schedule {schedule.name!r} with repetitions={schedule.repetitions}. " "In bragi_quantum.experiments's assumptions, this argument must be 1. Express " "schedule-level averaging with a loop register instead: " "`with schedule.loop(self.make_repetition_domain(repetitions)): ...` " "(the loop variable must not appear in any measure_system coords)." ) # The repetitions == 1 contract above guarantees a true top-level # tail position: the calibration block lands after the user's # loops but inside the same compiled program, and carries its own # repetition loop register — static regardless of the node's loop # style. calib_schedule = measurement_obj.calibration_points_schedule( self.parameters.repetitions ) if calib_schedule is not None: schedule.add(calib_schedule, label=cal.CALIBRATION_POINTS_LABEL) logger.info("📌 Appended calibration points.") elif self.require_calibration_points: raise ExperimentBuildingError( f"{type(self).__name__} requires calibration points " "(require_calibration_points=True) but they could not be " "appended: not every qubit in this node has a calibrated " "X gate." ) else: logger.warning( "📌⚠️ Calibration points requested (append_calibration_points=True) " "but skipped: not every qubit in this node has a calibrated X gate." ) logger.info(f"📋 Schedule created: {schedule.name}") logger.info(f" Operations count: {len(schedule.operations)}") # Log schedule resources (clocks, parameters) if hasattr(schedule, "resources"): logger.info(" Schedule resources:") for res_name, res_info in schedule.resources.items(): logger.info(f" - {res_name}: {res_info}") with timed( "Compilation took: ", timing_category=TimingTraceCategory.PREPARATION ): compiled_schedule = self.hardware_agent.compile(schedule) # Compiler drops the name; restore it (no property setter, but it's a dict key). compiled_schedule["name"] = schedule.name if self.append_calibration_points and calib_schedule is not None: # Verify against the compiled artifact itself — appending the # block pre-compile (above) is not proof it survived compilation # (e.g. a compiler-restructuring regression could silently drop # it; that's the very bug that motivated this check). if not cal.has_calibration_points(compiled_schedule): raise cal.CalibrationPointsError( "📌⚠️ Calibration points were appended before compilation but " "could not be found in the compiled schedule — compilation " "may have dropped them." ) # Log compiled schedule details logger.info( f" Compiled schedule instructions: {len(compiled_schedule.instructions) if hasattr(compiled_schedule, 'instructions') else 'N/A'}" ) logger.info( f" Compiled schedule resources: {list(compiled_schedule.resources.keys()) if hasattr(compiled_schedule, 'resources') else 'N/A'}" ) return compiled_schedule
[docs] def measure_compiled_schedule( self, compiled_schedule: CompiledSchedule, *, execution_mode: ExecutionMode | None = None, measurement: tuple[int, int] = (1, 1), ) -> xarray.Dataset: """ Execute a measurement for a node and save the resulting dataset. Args: compiled_schedule (CompiledSchedule): The compiled schedule to execute. execution_mode (ExecutionMode | None): The execution mode. If None, falls back to the active session's session_options. measurement (tuple): Tuple of (current_measurement, total_measurements). Returns: xarray.Dataset: The dataset containing the measurement results. """ if execution_mode is None: execution_mode = ExecutionMode[self._execution_mode.lower()] logger.info("Executing measurement via HardwareAgent...") logger.info(f" Cluster mode: {execution_mode}") raw_dataset = execute_schedule( compiled_schedule, self.hardware_agent, execution_mode=execution_mode, measurement=measurement, data_path=self.dataset_directory, cluster_names=self._cluster_names, save_cluster_metadata_to_disk=self._save_cluster_metadata_to_disk, ) # Check raw data from cluster for NaN values logger.info("Measurement completed. Inspecting acquired data...") for var in raw_dataset.data_vars: data = raw_dataset[var].values.flatten() nan_count = np.sum(np.isnan(data)) total = len(data) logger.info( f"Raw cluster data [{var}]: {total} points, {nan_count} NaN values" ) if nan_count == 0 and total > 0: logger.info(f" ✓ Data range: [{np.min(data):.6e}, {np.max(data):.6e}]") elif nan_count > 0 and nan_count < total: valid_data = data[~np.isnan(data)] logger.warning(f" ⚠️ Partial NaN: {nan_count}/{total} invalid") if len(valid_data) > 0: logger.info( f" Valid data range: [{np.min(valid_data):.6e}, {np.max(valid_data):.6e}]" ) else: logger.error(f" ❌ ALL DATA IS NaN! ({nan_count}/{total})") logger.error( f" Dataset structure: data_vars={list(raw_dataset.data_vars)}, coords={list(raw_dataset.coords)}" ) logger.error(f" Dimensions: {dict(raw_dataset.dims)}") # Log dataset attributes that might indicate measurement failure if hasattr(raw_dataset, "attrs"): logger.info(f"Dataset attributes: {raw_dataset.attrs}") # temporary fix for automatic mixer correction # The problem: when running multiple measurements in the same node, the mixer # correction values are not updated on the consecutive measurements with timed( "Invalidate cluster parameter cache took: ", timing_category=TimingTraceCategory.MEASUREMENT, ): for cluster_name in self._cluster_names: cluster_obj = Instrument.find_instrument(cluster_name) cluster_obj._invalidate_qcodes_parameter_cache() with timed( "Configure dataset took: ", timing_category=TimingTraceCategory.MEASUREMENT ): result_dataset = self.configure_dataset(raw_dataset) logger.info("Finished measurement") return result_dataset
[docs] def calibrate(self, data_path: Path): """ Execute the calibration workflow for this node. Args: data_path (Path): Directory where measurement results will be saved. """ # Convert execution_mode string to ExecutionMode enum (values are lowercase) try: execution_mode = ExecutionMode[self._execution_mode.lower()] except KeyError: valid_modes = [m.name for m in ExecutionMode] raise ValueError( f"Invalid execution_mode: '{self._execution_mode}'. " f"Valid modes are: {valid_modes}" ) # Analysis-only nodes (no measurement class) have nothing to measure; # their analysis input comes from redis, not an acquisition dataset. if self.measurement_cls is not None: result_dataset = self.measure_node(execution_mode=execution_mode) # TODO: FIX --> this is now returning an empty dataset save_dataset(result_dataset, self.name, data_path) self.post_process(data_path) logger.info("analysis completed")
def _apply_qoi_to_device(self, element_id: str, qoi: "BaseQoi") -> None: """Apply calibrated QOI values to the live QuantumDevice object. Parses to_redis_dict() keys of the form 'submodule:field' and assigns the value directly on the element. Logs each update and warns for keys that don't map to an existing submodule or field. """ if not qoi.is_successful: return if "_" in element_id: element = self.device.edges.get(element_id) else: element = self.device.elements.get(element_id) if element is None: logger.warning( f"Element '{element_id}' not found in device — skipping device update." ) return for redis_key, result in qoi.to_redis_dict().items(): parts = redis_key.split(":") if len(parts) != 2: continue submodule_name, field_name = parts submodule = getattr(element, submodule_name, None) if submodule is None: logger.warning( f"Device update skipped: '{element_id}' has no submodule '{submodule_name}'." ) continue if not hasattr(submodule, field_name): logger.warning( f"Device update skipped: '{element_id}.{submodule_name}' has no field '{field_name}'." ) continue setattr(submodule, field_name, result["value"]) logger.info( f"Device updated: {element_id}.{submodule_name}.{field_name} = {result['value']}" )
[docs] def post_process(self, data_path: Path): """ Execute post-measurement analysis and generate reports. This always runs (unless in dummy mode) to ensure plots and reports are generated. """ # Skip fitting dummy acquisition data — but analysis-only nodes read # their input from redis, not from a measured dataset, so they always # run their analysis regardless of mode. if self._execution_mode == "dummy" and self.measurement_cls is not None: logger.info("⏭️ Skipping analysis in dummy mode") return try: logger.info(f"📊 Starting analysis for {self.parameters.name}...") analysis: Analysis = self.analysis_cls( parameters=self.parameters, qoi_cls=self.qoi_cls, ) # Updating attributes for report generation analysis.pdf_report_path = self.pdf_report_path analysis.produce_support_figures = self.produce_support_figures dataset_file = data_path / f"dataset_{self.parameters.name}_0.hdf5" with timed( "Analysis fit took: ", timing_category=TimingTraceCategory.ANALYSIS ): self._results = analysis.run(dataset_file) analysis.save(data_path) logger.info( f"✅ Analysis completed. Generated {len(self._results)} results." ) # Build a single results dict for the timeline below. results_by_element: dict = {} for element_id_, qois_ in self._results.items(): params_dict = ( qois_.model_dump() if hasattr(qois_, "model_dump") else dict(qois_) ) results_by_element[element_id_] = params_dict # Record this node as the next step in the session timeline. try: timeline = ActiveSession.get_session_timeline() node_params = ( self.parameters.model_dump(mode="json") if hasattr(self.parameters, "model_dump") else dict(self.parameters) ) with timed( "Session timeline record took: ", timing_category=TimingTraceCategory.LOGGING, ): timeline.record_node_execution( node_name=self.parameters.name, node_class=self.__class__.__name__, parameters=node_params, target_qubits=list(results_by_element.keys()), results=results_by_element, replot_meta=self._build_replot_metadata(), ) except Exception as e: logger.warning(f"Could not record session timeline step: {e}") for element_id_, qois_ in self._results.items(): self._apply_qoi_to_device(element_id_, qois_) # Mirror the full analysis output (including quantities the live # QuantumDevice cannot hold) into the DeviceConfiguration. if self.device_config is not None: self.device_config.record_analysis_results( element_id_, self.name, qois_ ) update_redis_trusted_values( self.name, element_id_, qoi=qois_, redis_connection=self.redis_connection, ) # Record cross-cutting metadata once per node run: last experiment # timestamp, last node, and the components it successfully calibrated. calibrated_components = [ element_id_ for element_id_, qois_ in self._results.items() if getattr(qois_, "is_successful", False) ] if self.redis_connection is not None and calibrated_components: record_calibration_metadata( redis_connection=self.redis_connection, node=self.name, components=calibrated_components, ) except Exception as e: logger.error(f"❌ Analysis failed for {self.parameters.name}: {e}") logger.error(f"Traceback: {e.__traceback__}") raise # Re-raise to let orchestra know analysis failed return self._results
[docs] def configure_dataset( self, raw_ds: xarray.Dataset, ) -> xarray.Dataset: ds_utils.validate_raw_dataset(raw_ds, self.transmons) # Calibration points (appended by precompile via # calibration_points_schedule) arrive on dedicated CAL_ acquisition # channels. Split them into per-qubit "<qubit>_CAL" data variables # first, so the sweep processing below never sees them — in # particular, their "<qubit>_CAL" coordinates don't match any # schedule_samplespace dimension and would otherwise be dropped by # drop_active_reset_and_extra_coords below. raw_ds, calib_data_vars = self._extract_calibration_points(raw_ds) ds = ds_utils.drop_active_reset_and_extra_coords( raw_ds, self.schedule_samplespace ) ds = ds.squeeze(dim=None, drop=True) ds = ds_utils.rename_channels_to_qubit_names(ds, self.transmons) dimension_names = ds_utils.resolve_dimension_names( self.schedule_samplespace, raw_ds ) transmons_sorted = ds_utils.sorted_by_acq_channel(self.transmons) per_channel_datasets = ds_utils.build_channel_datasets( ds, transmons_sorted, dimension_names ) merged_ds = ds_utils.merge_channel_datasets(per_channel_datasets) # Attach the calibration points as their own data variables (with a # "CAL" dimension holding the prepared state labels). if calib_data_vars: merged_ds = merged_ds.assign(calib_data_vars) return merged_ds
def _extract_calibration_points( self, ds: xarray.Dataset ) -> tuple[xarray.Dataset, dict[str, xarray.DataArray]]: """Split calibration-point acquisitions off their dedicated channels. The calibration block appended by :meth:`BaseMeasurement.calibration_points_schedule` acquires on dedicated ``CAL_<n>`` acquisition channels, so the calibration data arrives as its own ``CAL_<n>`` data variables (with a ``<qubit>_CAL`` coordinate holding the prepared-state labels) and never touches the sweep's flat acquisition dimensions. Returns the dataset without the ``CAL_*`` variables and coordinates, together with a dict mapping ``"<qubit>_CAL"`` to a ``DataArray(CAL=[...])`` holding the hardware-averaged complex IQ value per prepared state. ``calibration_points_schedule`` requires every qubit to have a calibrated X gate before it produces any block at all, so whenever calibration data is present every qubit here shares the same ``CAL`` labels. """ channel_to_qubit = { int(t.measure.acq_channel): t.name for t in self.transmons.values() } calib_data_vars: dict[str, xarray.DataArray] = {} for var in list(ds.data_vars): name = str(var) if not name.startswith("CAL_"): continue qubit_name = channel_to_qubit[int(name.removeprefix("CAL_"))] acq_dim = next(d for d in ds[var].dims if str(d).startswith("acq_index")) state_labels = ds.coords[f"{qubit_name}_CAL"].values.astype(float) calib_da = ( ds[var] .reset_coords(drop=True) .rename({acq_dim: "CAL"}) .assign_coords(CAL=state_labels) ) calib_data_vars[f"{qubit_name}_CAL"] = calib_da ds = ds.drop_vars([var]) leftover_coords = [c for c in ds.coords if str(c).endswith("_CAL")] if leftover_coords: ds = ds.drop_vars(leftover_coords) return ds, calib_data_vars
[docs] class QubitNode(BaseNode, abc.ABC): def __init__( self, parameters: BaseParameters, qoi_cls: BaseQoi, ): super().__init__(parameters, qoi_cls) self.plots_per_qubit = 1 # can be 0 or 1 or 2 @override def _build_measurement(self): return self.measurement_cls(self.transmons) @property def transmons(self) -> dict[str, ExtendedTransmon]: """ Return transmons (qubits) restricted to this node's parameters.qubits. """ return { k: v for k, v in self.device.elements.items() if k in self.parameters.qubits } @override def __str__(self): return f"Node representation for {self.name} on qubits {self.all_qubits}" @override def __format__(self, message): return f"Node representation for {self.name} on qubits {self.all_qubits}" @override def __repr__(self): return f"Node({self.name}, {self.all_qubits})"
[docs] class CouplerNode(BaseNode, abc.ABC): def __init__( self, parameters: BaseParameters, qoi_cls: BaseQoi, ): super().__init__(parameters, qoi_cls) self.couplers = parameters.couplers # Coupler analogue of BaseNode.parameters_by_qubit: resolve per-coupler # overrides once so coupler nodes read ``self.parameters_by_coupler[c].<field>``. self.parameters_by_coupler = parameters.resolved_by_coupler() self.all_qubits = sorted(set(self.get_coupled_qubits())) self.plots_per_qubit = 1 # can be 0 or 1 or 2 self.validate() @override def _build_measurement(self): return self.measurement_cls( self.device.qubits, self.device.couplers, ) @property def edges(self) -> dict[str, ExtendedCompositeSquareEdge]: """ Return coupler edges restricted to this node's parameters.couplers. """ return {k: v for k, v in self.device.edges.items() if k in self.couplers}
[docs] def get_coupled_qubits(self) -> list: coupled_qubits = [] for coupler in self.couplers: qubits = coupler.split(sep="_") coupled_qubits.append(qubits[0]) coupled_qubits.append(qubits[1]) return coupled_qubits
[docs] def validate(self) -> None: all_coupled_qubits = [] for coupler in self.couplers: all_coupled_qubits += coupler.split("_") if len(all_coupled_qubits) > len(set(all_coupled_qubits)): logger.info("Couplers share qubits") raise ValueError("Improper Couplers")